169052
Alt: CTS-C1-BP-CC-FLX-AP-VSA-169052
Transponder-Coded Safety Switch, RFID, Closed-Current, Monitoring Outputs Door Position 1 (OD) / Guard Locking (OL) and Escape Release (OER), PVC Connection Cable 25 cm Length, M12 Plug Connector 8-Pin
- Weight:
- 1.36 LBS
- Minimum Purchase:
- 1 unit
The Euchner CTS transponder-coded safety switch with guard locking uses FlexFunction: the actuator configures the switch during setup, so guard lock monitoring is active or inactive and code evaluation runs at a high or low coding level depending on the actuator selected. One switch type can therefore cover both personnel protection and process protection applications, and BR versions can be integrated into a BR device chain.
Key Features
- FlexFunction configuration by function actuator (guard lock monitoring on/off, high or low coding level)
- C1 versions: guard locking by spring force, released with power ON (closed-circuit current principle)
- C2 versions: open-circuit current principle with guard locking for process protection
- Monitoring outputs for guard locking and door position
- BR versions: up to 20 switches in series
- Auxiliary release on front and rear side; escape release can be retrofitted on the rear side
Certifications
- Up to Category 4 / PL e according to EN ISO 13849-1