-
Available Now!
Available Now!Weg
CWB110-11-30D39
IEC Contactor, 110 Amp (110A), 1NO/1NC Auxiliary Contacts, 3NO, 480VAC, 50/60Hz, Screw Terminal, UL508
$193.62$193.62 -
Available Now!
Available Now!Weg
PESW-B40D39AX-R70
Enclosed Starter, 40 Amp (40A) CWB Contactor, 480VAC Coil Voltage, Start/Stop, 25-40A Overload Range, Three Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M06 Box Dimensions: 13 x 7.5 x 5.6 (HWD)
$247.60$247.60 -
Available Now!
Available Now!Weg
PESW-B40D15AX-R70
Enclosed Starter, 40 Amp (40A) CWB Contactor, 120VAC Coil Voltage, Start/Stop, 25-40A Overload Range, Three Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M06 Box Dimensions: 13 x 7.5 x 5.6 (HWD)
$320.10$320.10 -
Available Now!
Available Now!Weg
RWM112E-3-R4U112
Overload Relay, Solid State, 3 Pole, 28-112A, Adjustable Trip Class: 10, 20 or 30, Selectable Local and Remote Reset Modes, Use with CWM50 to CWM105 Contactor Models
$168.05$168.05 -
Available Now!
Available Now!Weg
ESW-B50D39A-R71
Enclosed Starter, 50 Amp (50A) CWB Contactor, 480VAC, 50/60Hz, Start/Stop + Reset, 32-50A Overload Range, Three Phase, NEMA 1, Metallic Enclosure, Non-Combination Across the Line Starter, M06 Box Dimensions: 13 x 7.5 x 5.6 (HWD)
$256.71$256.71 -
Available Now!
Available Now!Weg
PESWS-B50V24AX-RM71
Enclosed Starter, 50 Amp (50A) CWB Contactor, 208-240VAC Coil Voltage, Start/Stop, 32-50A Overload Range, Single Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M06 Box Dimensions: 13 x 7.5 x 5.6 (HWD)
$256.08$256.08 -
Available Now!
Available Now!Weg
RWB40E-3-R4U008
Overload Relay, Solid State, 3 Pole, 1.6-8A, Adjustable Trip Class: 10, 20 or 30, Selectable Local and Remote Reset Modes, Use with CWB9 to CWB38 Contactor Models
$64.58$64.58 -
Available Now!
Available Now!Weg
RW67-5D2-U050
Overload Relay, 2 Pole, 32-50A, Class 10, 2.87 x 1.97 x 4.17" (HWD), Use with CWB40 to CWB80 and CWBN2 Contactor Models
$62.61$62.61 -
Available Now!
Available Now!Weg
PESWS-B38V24AX-RM69
Enclosed Starter, 38 Amp (38A) CWB Contactor, 208-240VAC Coil Voltage, Start/Stop, 25-40A O/L Range, Single Phase, NEMA 4X, Non-Metallic, Non Reversing Non-Combination Across the Line Starter, M04 Box: 9.5 x 5.5 x 5.0"(HWD)
$174.60$174.60 -
Available Now!
Available Now!Weg
PESW-B12V24AX-R64
Enclosed Starter, 12 Amp (12A) CWB Contactor, 208-240VAC Coil Voltage, Start/Stop, 8-12.5A Overload Range, 3 Phase, NEMA 4X, Non-Metallic, Non Reversing Non-Combination Across the Line Starter, M04 Box: 9.5 x 5.5 x 5.0"(HWD)
$132.11$132.11 -
Available Now!
Available Now!Weg
PESWS-B9D15AX-RM61
Enclosed Starter, 9 Amp (9A) CWB Contactor, 120VAC Coil Voltage, Start/Stop, 4-6.3A Overload Range, Single Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M04 Box Dimensions: 9.5 x 5.5 x 5.0" (HWD)
$81.48$81.48 -
Available Now!
Available Now!Weg
ESWS-B50V24E-RM71
Enclosed Starter, 50 Amp (50A) CWB Contactor, 208-240VAC, Reset Only, 32-50A O/L Range, Single Phase, NEMA 1, Metallic Enclosure, Non Reversing Non-Combination Across the Line Starter, M06 Box: 13 x 7.5 x 5.6 (HWD)
$210.21$210.21
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors