Weg
CWB80-11-30D02
IEC Contactor, 80 Amp (80A), 1NO/1NC Auxiliary Contacts, 3NO, 24VAC, 50/60Hz, Screw Terminal, UL508
$124.47$124.47 -
Weg
CWC07-10-30V18
Mini Contactor, 7 Amp, 1NO Auxiliary Contact, 3NO Power Poles, 110VAC, 50Hz/120VAC, 60Hz, Screw Terminal, IP20, 2.28 x 1.77 x 2.05" (HWD), CWC Series
$16.85$16.85 -
Weg
CWC09-10-30C03
Mini Contactor, 9 Amp, 1NO Auxiliary Contacts, 3NO Power Poles, 24VDC, Screw Terminal, IP20, 2.28" x 1.77" x 2..05" (HWD), CWC Series
$23.87$23.87 -
Weg
CWC09-10-30V24
Mini Contactor, 9 Amp, 1NO Auxiliary Contact, 3NO Power Poles, 180-208V 50Hz/208-240V 60Hz, Screw Terminal, IP20, 2.28 x 1.77 x 2.05" (HWD), CWC Series
$18.25$18.25 -
$44.95$44.95 -
Weg
CWM25-00-20V18
IEC Contactor, 25 Amp (25A), 2NO Main Contact, 110-130VAC, 50Hz/60Hz-DC, Screw Terminal, IP20 Main/Control Circuit, 81 x 45 x 87mm (3.19 x 1.77 x 3.43") (HWD)
$50.00$50.00 -
Weg
CWM32N-00-30V18
NEMA Contactor, 32 Amp (32A) (N), 3NO Main Contact, 110-130VAC, 50Hz/60Hz-DC, Screw Terminal, IP00 Main Circuit, IP20 Control Circuit, 162.5 x 118 x 147mm (6.40 x 4.65 x 5.79") (HWD)
$82.82$82.82 -
Weg
CWM800-22-30E35
Contactor, IEC, 800 Amps, 2NO/2NC, 100-127VAC/DC, 3-Pole, UL508, Use RW Overload Relay
$3,297.65$3,297.65 -
$36.36$36.36 -
Weg
ESW-B50V24A-R70
Enclosed Starter, 50 Amp (50A) CWB Contactor, 208-240VAC Coil Voltage, Start/Stop, 25-40A O/L Range, 3 Phase. NEMA 1, Metallic Enclosure, Non Reversing Non-Combination Across the Line Starter, M06 Box: 13 x 7.5 x 5.6" (HWD)
$256.71$256.71 -
Weg
ESW-B65V24E-R72
Enclosed Starter, 65 Amp (65A) CWB Contactor, 208-240VAC Coil Voltage, Reset Only, 40-57A O/L Range, 3 Phase. NEMA 1, Metallic Enclosure, Non Reversing Non-Combination Across the Line Starter, M06 Box: 13 x 7.5 x 5.6 (HWD)
$238.88$238.88 -
Weg
ESWE-B9D15KX-D07
Enclosed Starter for 1/2hp@200V, 1/2hp@230V, 1-1/2hp@460V, 1-1/2hp@575V Maximum hp 3-Phase Motor, 9 Amp CWB Contactor, 120VAC Coil Voltage without CPT, 50/60Hz, 1.6 - 2.5 Amp MPW40 Overload Relay
$572.85$572.85
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors