F71BHK

F71BHK

Alt: Available Only While Factory Stock Lasts!

$141.07

Fiber Optic Sensor, Digital Display, NPN, Blue LED

Minimum Purchase:
1 unit
Adding to cart… The item has been added
Description
Fiber Optic Sensor, Digital Display, NPN, Blue LED

Features Include:

  • Digital display
  • Auto sensitivity setting
  • Manual sensitivity setting
  • The "new" wire saving connection system compatible with major fiber amplifier models
  • Current Consumption: 35mA or less
  • Operation Mode: Light ON/Dark ON selecting operation (by switch)
  • Timer: Off delay/disabled selectable, Delay time: 40 ms fixed
  • Response time: 30 μs or less
  • Light Source (wavelength): Blue LED (470nm)
  • Volume: SENS: sensitivity adjustment volume (8-turn indicator)
  • Display: LCD display with backlight
  • Material: Polycarbonate
  • Connection between amplifier units: Connector (for power supply) Input-output connection Connector: (using a dedicated connector cable *2)
  • Maximum number of attachments and detachments of connector: 50
  • Weight: Approx. 20 g, main unit only

Output Mode: 

  • Control output: Open collector output / Rating: Source current 100 mA (30 VDC) or less / Residual voltage: 1 V or less
  • Stability output: Open collector output / Rating: Source current 100 mA (30 VDC) or less / Residual voltage: 1 V or less

Indicator: 

  • Orange LED: Operation Indicator
  • Green LED: Stability Indicator

Default Settings:

  • Mode selector switch: L.ON (ON when light is received)
  • Timer selector switch: NOR (Output timer is OFF)

Switch: 

  • Light ON/Dark ON selector switch: L.ON for Light ON, D.ON for Dark ON
  • Timer selector switch: NOR. for ON/OFF operation, ON.D for on delay (40 ms), OFF.D for off delay (40 ms)

Environmental Specifications:

  • Ambient Light: Incandescent lamp: 10,000 lx / Sunlight: 20,000 lx
  • Ambient Humidity: 35 - 85%RH (non-condensing)
  • Vibration: 10 - 55 Hz / 1.5 mm double amplitude / 2 hours each in 3 direction
  • Shock: 500 m/s2 / 3 times each in 3 directions
  • Dielectric withstanding: 1000 VAC for 1 minute
  • Insulation resistance: 500 DVC, 20MΩ or more

Noise:

  • Power supply line: 500 V / Cycle: 10 ms / Pulse duration: 1 μs
  • Radiation: 1 kV / Cycle: 10 ms / Pulse duration 1 μs (with noise simulator)

Ambient Temperature:

  • 1-3 adjacent units in operation: -25 - +55°C
  • 4-10 adjacent units in operation: -25 - +50°C
  • 11-16 adjacent units in operation: -25 - +45°C
  • Storage: -40 - +70°C (non-freezing)