Safety Switches

Safety switches are the gatekeepers that prevent operation under unsafe conditions.

They make sure safety criteria are met before machine start-up or to continue running which minimizes or prevents risk.

Style:
Product Price Rating Action
  • Pilz_540100_Primary.png

    Pilz

    540304

    PSEN cs1.19n/PSEN cs1.19 1sw+OSSD1&2

    RFID Safety Switch, 2 Safe SC Outputs, 5-Pin M12 Male Connector, 4 Actuation Directions, Typical Operating Distance 21mm, Assured Operating Distance 15mm, Assured Release Distance 40mm, IP67, Includes 1 Coded Switch and 1 Actuator

  • Pilz_540305_Primary.png

    Pilz

    540305

    PSEN cs1.19n/PSEN cs1.19 1sw+OSSD1+OSSD2

    RFID Safety Switch, 2 Safe SC Outputs, 5-Pin M12 Male Connector, 4 Actuation Directions, Typical Operating Distance 21mm, Assured Operating Distance 15mm, Assured Release Distance 40mm, IP67, Includes 1 Coded Switch and 2 Actuators

  • Pilz_540353_Primary.png

    Pilz

    540353

    PSEN cs1.19n 1 switch

    RFID Safety Switch, 2 Safe SC Outputs, 5-Pin M12 Male Connector, 4 Actuation Directions, Switching Distance 21mm, Assured Operating Distance 15mm, Assured Release Distance 40mm, IP67, Actuator Must be Purchased Separately

  • Pilz_541003_Primary.png

    Pilz

    541003

    PSEN cs3.1n / PSEN cs3.1 1 Unit

    RFID Safety Switch, 2 Safe SC Outputs, 5-Pin M12 Male Connector, One Actuation Direction, Switching Distance 11mm, Assured Operating Distance 8mm, Assured Release Distance 20mm, IP67, Includes 1 Coded Switch and 1 Actuator

  • Pilz_541009_Primary.png

    Pilz

    541009

    PSEN cs3.1 M12/8-0.15m/PSEN cs3.1 1Unit

    RFID Safety Switch, 2 Safe SC Outputs, 8-Pin M12 Male Connector, One Direction, Support for SDD, Switching Distance 11mm, Assured Operating Distance 8mm, Assured Release Distance 20mm, Series Connection, IP67, Includes 1 Coded Switch and 1 Actuator

  • Pilz_541003_Primary.png

    Pilz

    541010

    PSEN cs3.1p /PSEN cs3.1 1unit

    RFID Safety Switch, 2 Safe SC Outputs, 8-Pin M8 Male Connector, One Actuation Direction, Support for SDD, Switching Distance 11mm, Assured Operating Distance 8mm, Assured Release Distance 20mm, IP67, Includes 1 Coded Switch and 1 Actuator

  • Pilz_541012_Primary.png

    Pilz

    541012

    PSEN cs3.1b /PSEN cs3.1 1unit

    RFID Safety Switch, 2 Safe SC Outputs, Connection Cable 10m, One Actuation Direction, Support for SDD, Switching Distance 11mm, Assured Operating Distance 8mm, Assured Release Distance 20mm, IP6K9K, Includes 1 Coded Switch and 1 Actuator, IP67

  • Pilz_541014_Primary.png

    Pilz

    541014

    PSEN cs3.1 M12/8-1.5m/PSEN cs3.1 1unit

    RFID Safety Switch, 2 Safe SC Output, 8-Pin M12 Male Connector, 1.5m Cable, One Actuation Direction, SDD Support, Switching Distance 11mm, Assured Operating Distance 8mm, Assured Release Distance 20mm, IP6K9K, Includes 1 Coded Switch and 1 Actuator

  • Pilz_541062_Primary.png

    Pilz

    541062

    PSEN cs3.1b 1 switch

    RFID Safety Switch, 2 Safe SC Outputs, Connection Cable 10m, One Actuation Direction, Typical Operating Distance 11mm, Assured Operating Distance 8mm, Assured Release Distance 20mm, IP6K9K, IP67

  • Pilz_541064_Primary.png

    Pilz

    541064

    PSEN cs3.1 M12/8-1.5m 1switch

    RFID Safety Switch, 2 Safe SC Outputs, 8-Pin M12 Male Connector, 1.5m Cable, One Actuation Direction, SDD Support, Switching Distance Depends on Actuator, Series Connection, IP67, Includes 1 Coded Switch and 1 Actuator

  • Pilz_541065_Primary.png

    Pilz

    541065

    PSEN cs3.1p Key 1 switch

    Safety Switch for Transponder Key PSEN cs4.1 Key, Coded, 24VDC, 2 OSSD Outputs, 1 Signal Output, M8 8-Pin Male Connector, Series Connectable, IP6K9K, Key Adapter and Key Must be Purchased Separately, IP67

  • Pilz_541103_Primary.png

    Pilz

    541103

    PSEN cs4.1n / PSEN cs4.1 1 Unit

    RFID Safety Switch, 2 Safe SC Output, 5-Pin M12 Connector, One Actuation Direction, Switching Distance 11mm, Assured Operating Distance 8mm, Assured Release Distance 20mm, Max 8 Teach-In Processes, IP67, Includes 1 Fully Coded Switch and 1 Actuator

Safety switches are the gatekeepers that prevent operation under unsafe conditions.

They make sure safety criteria are met before machine start-up or to continue running which minimizes or prevents risk.