Contactors, Starters, Overload Relays

A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors

Style:
Product Price Rating Action
  • Available Now!
    weg_esw_box4_reset_onoff_64__10037.jpg
    Available Now!

    Weg

    ESWS-B18V24A-RM32

    Enclosed Starter, 18A, 208-240VCoil, Start/Stop + Reset , 11-17A Overload Range, Single Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination

  • Available Now!
    weg_esw_box4_reset_onoff_18__03258.jpg
    Available Now!

    Weg

    ESW-B25D39A-R33

    Enclosed Starter, 7.5hp@230V, 25 Amp (25A), 480V Coil, Start/Stop+Reset, 15-23A (RW27) Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination

  • Available Now!
    weg_esw_box4_reset_22__43060.jpg
    Available Now!

    Weg

    ESW-B32V24E-R34

    Enclosed Starter, 10hp@230V, 32A, 208-240V Coil, Reset Only, NEMA 1, 22-32A Overload Range, 3 Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination

  • Available Now!
    weg_esw_box4_reset_onoff_19__37889.jpg
    Available Now!

    Weg

    ESW-B25V24A-R33

    Enclosed Starter, 7.5hp@230V, 25A, 208-240V Coil, Start/Stop+Reset, NEMA 1, 15-23A Overload Range, 3 Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination

  • Available Now!
    weg_esw_box4_reset_19__26404.jpg
    Available Now!

    Weg

    ESW-B25V24E-R33

    Enclosed Starter, 7.5hp@230V, 25A, 208-240V Coil, Reset Only, NEMA 1, 15-23A Overload Range, 3 Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination

  • Available Now!
    weg_esw_box4_reset_onoff_20__80997.jpg
    Available Now!

    Weg

    ESW-B32D15A-R34

    Enclosed Starter, 10hp@230V, 32 Amp (32A), 120V Coil, Start/Stop+Reset, 22-32A (RW27) Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination

  • Available Now!
    weg_esw_box4_reset_onoff_21__86892.jpg
    Available Now!

    Weg

    ESW-B32D39A-R34

    Enclosed Starter, 10hp@230V, 32 Amp (32A), 480V Coil, Start/Stop+Reset, 22-32A (RW27) Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination

  • Available Now!
    weg_esw_box4_reset_onoff_34__36641.jpg
    Available Now!

    Weg

    ESW-B9D39A-R24

    Enclosed Starter, 1hp@460V, 9 Amp (9A), 480V Coil, Start/Stop+Reset, 1.2-1.8A (RW27) Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination

  • Available Now!
    weg_esw_box4_reset_onoff_13__02992.jpg
    Available Now!

    Weg

    ESW-B12D39A-R30

    Enclosed Starter, 7.5hp@460V, 12 Amp (12A), 480V Coil, Start/Stop+Reset, 8-12.5A (RW27) Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination

A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors