-
LS Electric
0705104300
Manual Motor Starter, 6 Amp, (4-6A), High Breaking Capacity, Overload & Instantaneous Protection, This is the Latest Version of (0705000900, 705000900, MMS-32H 6A EXP)
$67.33$67.33 -
Available Now! Available Now!LS Electric
1337012900
IEC Contactor, General Purpose, MC-40a, 120VAC, Metasol, MC-Series
$82.58$82.58 -
Available Now! Available Now!Weg
CWB9-11-30D15
IEC Contactor, 9 Amp (9A), 1NO/1NC Auxiliary Contacts, 3NO, 120VAC, 50/60Hz, Screw Terminal, UL508
$29.25$29.25 -
Available Now! $28.00$28.00 -
Available Now! Available Now!Weg
ESW-B25V24E-R33
Enclosed Starter, 7.5hp@230V, 25A, 208-240V Coil, Reset Only, NEMA 1, 15-23A Overload Range, 3 Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination
$120.42$120.42 -
Available Now! Available Now!LS Electric
1298001400
Overload Relay, MT-32 15A 3K, Class 10, Screw Terminals, Only Use with MC-9B, MC-12B, MC-18B, MC-32B, and MC-40B Series Contactors
$48.16$48.16 -
Noark
Ex9CK20A20B7
DP (Definite Purpose) Contactor, Screw Terminals, 20 Amp (20A), 2NO, 24VAC, 50/60Hz, Ex9CK Series
$15.40$15.40 -
Noark
Ex9CKT32B20Y7
DP (Definite Purpose) Contactor, Lug Terminals, 32 Amp (32A), 2NO, 600VAC, 50/60Hz, Ex9CK Series
$18.27$18.27 -
Available Now! Available Now!Noark
EX9CK40B20G7
DP (Definite Purpose) Contactor, Lug Terminals, 40 Amp (40A), 2NO, 120VAC, 50/60Hz, Ex9CK Series
$22.54$22.54 -
Available Now! Available Now!Weg
PESW-B25D39AX-R67
Enclosed Starter, 7.5hp@230V / 15hp@460V, 25A, 480V Coil, Start / Stop+Reset, 15-23A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$137.63$137.63 -
Available Now! Available Now!Weg
CWB9-11-30D39
IEC Contactor, 9 Amp (9A), 1NO/1NC Auxiliary Contacts, 3NO, 480VAC, 50/60Hz, Screw Terminal, UL508
$29.25$29.25 -
Carlo Gavazzi
CGE40-2P-40AN
Contactor Overload, Electronic Overload for CC32 and CC40 Contactors, Monitoring of 2-Poles, CC SSOLR 2P 40A 8-40A
$172.74$172.74
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors