Contactors, Starters, Overload Relays

A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors

Style:
Product Price Rating Action
  • Image coming soon

    Weg

    ESW-B12D39C-R29

    17110050

    Enclosed Starter, 12A CWB Contactor, 480VAC Coil, On/Off Selector Switch + Reset, 7-10A Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination

  • Image coming soon

    Weg

    ESW-B80D15E-R75

    16513903

    Enclosed Starter, 25hp@230V / 50hp@460V, 80A CWB Contactor, 120VAC Coil, Reset Only, 63-80A Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination

  • Image coming soon

    Weg

    ESW-B12D35A-R30

    15494544

    Enclosed Starter, 3hp@200V / 3hp@230V / 7.5hp@460V / 10hp@575V, 12A CWB Contactor, Start/Stop + Reset, 8-12.5A Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Non-Reversing, Non-Combination

  • Image coming soon

    Weg

    ESW-B65V24A-R73

    16346582

    Enclosed Starter, 15hp@200V / 20hp@230V / 40hp@460V / 50hp@575V, 65A CWB Contactor, 208-240VAC Coil, Start/Stop + Reset, 50-63A O/L Range, 3 Phase, NEMA 1 Metallic, Non-Reversing, Non-Combination

  • Image coming soon

    Weg

    CWM80-11-30V24

    10857196

    IEC Contactor, 80 Amp (80A), 1NO/1NC Auxiliary Contacts, 3NO, 180-208V 50Hz/208-240V 60Hz Coil, 50 HP @ 460V, UL File E202315, Use RW Overload Relay

  • Image coming soon

    Weg

    CWCA0-31-00V24

    12680545

    Mini Contactor Control Relay, 10 Amp, 3NO/1NC, No Main Contacts, 180-208V 50Hz/208-240V 60Hz Coil, A600/Q600 Rating, Screw or DIN Rail Mount, IP20, CWC Series

  • Image coming soon

    Weg

    ESW-B65D39A-R73

    16346583

    Enclosed Starter, 15hp@200V / 20hp@230V / 40hp@460V / 50hp@575V, 65A CWB Contactor, 480VAC Coil, Start/Stop + Reset, 50-63A O/L Range, 3 Phase, NEMA 1 Metallic, Non-Reversing, Non-Combination

  • Image coming soon

    Weg

    ESW-B12D15H-R30

    14662955

    Enclosed Starter, 3hp@200V / 3hp@230V / 7.5hp@460V / 10hp@575V, 12A CWB Contactor, 120VAC Coil, HOA + Reset, 8-12.5A Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Non-Reversing, Non-Combination

A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors