A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors

Style:
Product Price Rating Action
  • weg_esw_box4_reset_onoff_39__72710.jpg

    Weg

    ESW-B9V24A-R23

    Enclosed Starter, 9 Amp (9A), CWB Contactor, 180-208VAC, 50Hz | 208-240VAC, 60Hz, Start/Stop+Reset, 0.8-1.2A O/L Range, 3 Phase NEMA 1 Metallic Enclosure, Full Voltage Non-Combination Across the Line Starter, M04 Box: 9.5 x 5.5 x 5.0" (HWD)

  • mms-100s_7__51359.jpg

    LS Electric

    0707100300

    Manual Motor Starter, 26A, (18-26A), 100F, Standard. Breaking Capacity, Overload & Instantaneous Protection, NCNR, This is the Latest Version of (0707000300, 707000300, MMS-100S 26A EXP)

  • mms-32s_5__86739.jpg

    LS Electric

    0705101200

    Manual Motor Starter, 13A, (9-13A), 32F, Standard Breaking Capacity, Overload & Instantaneous Protection, This is the Latest Version of (0705004400, 705004400, MMS-32S 13A EXP)

  • mms-32h_14__98661.jpg

    LS Electric

    0705105300

    Manual Motor Starter, 0.25A, 32F, High Breaking Capacity, Instantaneous Protection Only, NCNR, This is the Latest Version of (0705001800, 705001800, MMS-32HI 0.25A EXP)

  • weg_esw_box4_reset_onoff_40__30914.jpg

    Weg

    ESW-B9V24A-R25

    Enclosed Starter, 0.75hp@230V, 9A, 208-240V Coil, Start/Stop+Reset, NEMA 1, 1.8-2.8A Overload Range, 3 Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination

  • mms-100s_6__92487.jpg

    LS Electric

    0707100400

    Manual Motor Starter, 32A, (22-32A), 100F, Standard. Breaking Capacity, Overload & Instantaneous Protection, NCNR, This is the Latest Version of (0707000400, 707000400, MMS-100S 32A EXP)

  • mms-32s_4__23676.jpg

    LS Electric

    0705101300

    Manual Motor Starter, 17A, (11-17A), 32F, Standard Breaking Capacity, Overload & Instantaneous Protection, This is the Latest Version of (0705004500, 705004500, MMS-32S 17A EXP)

  • mms-32h_15__98165.jpg

    LS Electric

    0705105200

    Manual Motor Starter, 0.16A, 32F, High Breaking Capacity, Instantaneous Protection Only, NCNR, This is the Latest Version of (0705001700, 705001700, MMS-32HI 0.16A EXP)

  • mms-100s_5__06140.jpg

    LS Electric

    0707100500

    Manual Motor Starter, 40A, (28-40A), 100F, Standard. Breaking Capacity, Overload & Instantaneous Protection, NCNR, This is the Latest Version of (0707000500, 707000500, MMS-100S 40A EXP)

  • mms-32s_3__81144.jpg

    LS Electric

    0705101400

    Manual Motor Starter, 22A, (14-22A), 32F, Standard Breaking Capacity, Overload & Instantaneous Protection, This is the Latest Version of (0705004600, 705004600, MMS-32S 22A EXP)

A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors