Weg
CWM112-22-30E13
10535745
IEC Contactor, 112 Amp (112A), 2NO/2NC Auxiliary Contacts, 3NO, 208-250VAC/VDC 50/60Hz Electronic Module Coil, 100 HP @ 460V, Built-In Surge Suppressor, UL File E202315, Use RW Overload Relay
$436.82$436.82 -
Weg
ESW-B18V24E-R29
13349851
Enclosed Starter, 18A CWB Contactor, 208-240VAC Coil, Reset Only, 7-10A Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination
$119.76$119.76 -
Weg
ESWC-18TM1K9-RE3
14877238
Enclosed Combination Starter, Non-Reversing, 18A, 208V/3-5hp | 240V/3-5hp | 480V/7.5-10hp, 5-25A Solid-State Overload, 208/230/460V-120V CPT, Reset/Start/Stop/HOA/Run Light, Type 1/3R/4/12 Metallic
$1,453.90$1,453.90 -
Weg
PESW-B80D39AX-R75
16346630
Enclosed Starter, 25hp@230V / 50hp@460V, 80A CWB Contactor, 480VAC Coil, Start/Stop + Reset, 63-80A Overload Range, 3 Phase, NEMA 4X Non-Metallic Enclosure, Non-Reversing, Non-Combination
$395.76$395.76 -
Weg
CWM32N-11-30V18
11697422
NEMA Contactor, Size 1, 32 Amp (32A), 3NO Main Contact, 1NO/1NC Auxiliary Contacts, 110V 50Hz/120V 60Hz Coil, 10 HP @ 460V, UL File E202315
$80.80$80.80 -
Weg
ESW-B9D33E-R28
14556688
Enclosed Starter, 2hp@200V / 2hp@230V / 5hp@460V / 5hp@575V, 9A CWB Contactor, Reset Only, 5.6-8A Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination
$100.01$100.01 -
Weg
CWM32-11-30V18
10046154
IEC Contactor, 32 Amp (32A), 1NO/1NC Auxiliary Contacts, 3NO, 110V 50Hz/120V 60Hz Coil, 20 HP @ 460V, UL File E202315, Use RW Overload Relay
$80.80$80.80 -
Weg
CWB18-11-30C02
12856627
IEC Contactor, 18 Amp (18A), 1NO/1NC Auxiliary Contacts, 3NO, 10 HP @ 480V, UL File E202315
$56.93$56.93 -
Weg
ESW-B18D45E-R32
14671257
Enclosed Starter, 3hp@200V / 5hp@230V / 10hp@460V / 15hp@575V, 18A CWB Contactor, 600VAC Coil, Reset Only, 11-17A Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Non-Reversing, Non-Combination
$119.76$119.76 -
Weg
CWM112-22-30E10
10535740
IEC Contactor, 112 Amp (112A), 2NO/2NC Auxiliary Contacts, 3NO, 110-130VAC/VDC 50/60Hz Electronic Module Coil, 100 HP @ 460V, Built-In Surge Suppressor, UL File E202315, Use RW Overload Relay
$436.82$436.82 -
Weg
PESW-B80D39AX-R74
14970976
Enclosed Starter, 20hp@200V / 25hp@230V / 50hp@460V, 80A CWB Contactor, 480VAC Coil, Start/Stop + Reset, 57-70A Overload Range, 3 Phase, NEMA 4X Non-Metallic Enclosure, Non-Reversing, Non-Combination
$378.30$378.30 -
Weg
ESWC-180TM1K9-RE7
14877408
Enclosed Combination Starter, Non-Reversing, 180A, 208V/50-60hp | 240V/50-60hp | 480V/100-150hp, 50-250A Solid-State Overload, 208/230/460V-120V CPT, Reset/Start/Stop/HOA/Run Light, Type 1/3R/4/12, (Cannot Ship UPS, Drop Ship Only via Truck)
$4,381.80$4,381.80
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors