Weg
PESW-B9D45AX-R63
15312931
Enclosed Starter, 2hp@200V / 3hp@230V / 5hp@460V / 7.5hp@575V, 9A CWB Contactor, 600VAC Coil, Start/Stop + Reset, 7-10A O/L Range, 3 Phase, NEMA 4X Non-Metallic, Non-Reversing, Non-Combination
$122.22$122.22 -
Weg
ESW-B9D44E-R25
16041838
Enclosed Starter, 0.5hp@200V / 0.5hp@230V / 1hp@460V / 2hp@575V, 9A CWB Contactor, Reset Only, 1.8-2.8A Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination
$100.01$100.01 -
Weg
CWM95N-00-30V30
11697773
NEMA Contactor, Size 3, 95 Amp (95A), 3NO Main Contact, 240V 60Hz Coil, 50 HP @ 460V, UL File E202315
$193.92$193.92 -
Weg
ESWE-B25T04KX-D12
14540959
Enclosed Starter for 7.5hp@200V / 7.5hp@230V / 15hp@460V / 15hp@575V Max hp 3-Phase Motor, 25A CWB Contactor, 480V/120V CPT, 16-20A Manual Motor Protector, HOA/Start/Stop/Reset/Pilot Lights, NEMA 4X
$787.25$787.25 -
Weg
CWM50-11-30V24
10857193
IEC Contactor, 50 Amp (50A), 1NO/1NC Auxiliary Contacts, 3NO, 180-208V 50Hz/208-240V 60Hz Coil, 40 HP @ 460V, UL File E202315, Use RW Overload Relay
$118.67$118.67 -
Weg
CWM18-00-20V24
10046478
IEC Contactor, 2-Pole, 18 Amp (18A), 2NO, 180-208V 50Hz/208-240V 60Hz Coil, 3 HP @ 230V 1-Phase, UL File E202315
$36.87$36.87 -
Weg
ESW-B25V24C-R33
10072197
Enclosed Starter, 5hp@200V / 7.5hp@230V / 15hp@460V / 15hp@575V, 25A CWB Contactor, 208-240VAC Coil, On/Off Selector + Reset, 15-23A O/L Range, 3 Phase, NEMA 1 Metallic, Non-Reversing, Non-Combination
$175.81$175.81 -
Weg
CWC09-00-40C03
13390491
Mini Contactor, 9 Amp, 4NO Power Poles, 24VDC Coil, 5 HP @ 460V, Screw or DIN Rail Mount, IP20, CWC Series
$23.87$23.87 -
Weg
ESW-B9D39H-R28
14663041
Enclosed Starter, 2hp@200V / 2hp@230V / 5hp@460V / 5hp@575V, 9A CWB Contactor, 480VAC Coil, HOA + Reset, 5.6-8A Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Non-Reversing, Non-Combination
$149.40$149.40 -
Weg
PESW-B9D45AX-R61
15518431
Enclosed Starter, 1hp@200V / 1.5hp@230V / 3hp@460V / 5hp@575V, 9A CWB Contactor, 600VAC Coil, Start/Stop + Reset, 4-6.3A O/L Range, 3 Phase, NEMA 4X Non-Metallic, Non-Reversing, Non-Combination
$122.22$122.22 -
Weg
CWM50N-00-30V47
13231782
NEMA Contactor, Size 2, 50 Amp (50A), 3NO Main Contact, 400-415V 50Hz/480V 60Hz Coil, 25 HP @ 460V, UL File E202315
$117.67$117.67 -
Weg
CWM150-22-30E21
10535756
IEC Contactor, 150 Amp (150A), 2NO/2NC Auxiliary Contacts, 3NO, 430-500VAC/VDC 50/60Hz Electronic Module Coil, 125 HP @ 460V, Built-In Surge Suppressor, UL File E202315, Use RW Overload Relay
$484.80$484.80
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors