Weg
PESW-80V18AX-R41
Enclosed Starter, 25hp@230V / 50hp@460V / 60hp@575V, 80A, 120V Coil, Start / Stop+Reset, 4X, 57-70A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$378.30$378.30 -
Weg
PESW-80V18EX-R41
Enclosed Starter, 25hp@230V / 50hp@460V / 60hp@575V, 80A, 120V Coil, Reset Only, 57-70A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$345.21$345.21 -
Weg
PESW-80V47AX-R41
Enclosed Starter, 25hp@230V / 50hp@460V / 60hp@575V, 80A, 480V Coil, Start / Stop+Reset, 4X, 57-70A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$378.30$378.30 -
Weg
PESW-80V47EX-R41
Enclosed Starter, 25hp@230V / 50hp@460V / 60hp@575V, 80A, 480V Coil, Reset Only, 57-70A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$345.21$345.21 -
Weg
PESW-95V18AX-R43
Enclosed Starter, 30hp@230V / 60hp@460V / 75hp@575V, 95A, 120V Coil, Start / Stop+Reset, 4X, 63-80A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$640.20$640.20 -
Weg
PESW-95V18EX-R43
Enclosed Starter, 30hp@230V / 60hp@460V / 75hp@575V, 95A, 120V Coil, Reset Only, 63-80A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$631.47$631.47 -
Weg
PESW-95V24AX-R43
Enclosed Starter, 30hp@230V / 60hp@460V / 75hp@575V, 95A, 208-240V Coil, Start / Stop+Reset, 4X, 63-80A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$640.20$640.20 -
Weg
PESW-95V24EX-R43
Enclosed Starter, 30hp@230V / 60hp@460V / 75hp@575V, 95A, 208-240V Coil, Reset Only, 4X, 63-80A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$631.47$631.47 -
Weg
PESW-95V47EX-R43
Enclosed Starter, 30hp@230V / 60hp@460V / 75hp@575V, 95A, 480V Coil, Reset Only, 63-80A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$631.47$631.47 -
Weg
PESW-B12D15AX-R64
Enclosed Starter, 7.5hp@460V / 10hp@575V, 12A, 120V Coil, Start / Stop+Reset, 8-12A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$132.11$132.11 -
Weg
PESW-B12D45EX-R64
Enclosed Starter, 12 Amp (12A) CWB Contactor, 600V Coil Voltage, Reset Only, 8-12.5A Overload Range, Three Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M04 Box Dimensions: 9.5 x 5.5 x 5.0" (HWD)
$101.27$101.27 -
Weg
PESW-B12V24EX-R64
Enclosed Starter, 12 Amp (12A) CWB Contactor, 208-240VAC Coil Voltage, Reset Only, 8-12.5A Overload Range, 3 Phase, NEMA 4X, Non-Metallic, Non Reversing Non-Combination Across the Line Starter, M04 Box: 9.5 x 5.5 x 5.0"(HWD)
$101.27$101.27
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors