Weg
ESW-B9D15A-R24
Enclosed Starter, 1hp@460V, 9 Amp (9A), 120V Coil, Start/Stop+Reset, 1.2-1.8A (RW27) Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination
$133.77$133.77 -
Weg
ESWE-B18D15KX-D11
Enclosed Starter for 5hp@200V, 5hp@230V, 10hp@460V, 15hp@575V Maximum hp 3-Phase Motor, 18 Amp CWB Contactor, 120VAC Coil Voltage without CPT, 50/60Hz, 10 - 16 Amp MPW40 Overload Relay
$586.25$586.25 -
Weg
ESWE-B25D15KX-D12
Enclosed Starter for 7-1/2hp@200V, 7-1/2hp@230V, 15hp@460V, 15hp@575V Maximum hp 3-Phase Motor, 25 Amp CWB Contactor, 120VAC Coil Voltage without CPT, 50/60Hz, 16 - 20 Amp MPW40 Overload Relay
$603.00$603.00 -
Weg
ESWF-18V18N4-D11
Enclosed Starter, 5hp/200V, 5hp/230V, 10hp/460V, 15hp/575V, 120VAC Coil Voltage, 10-16A O/L Range, Wall Mount, Type 4/12 Metallic Enclosure, HOA-Start/Stop/Reset, Circuit Breaker Rotary Handle, FVNR Across the Line Starter
$1,001.65$1,001.65 -
$69.64$69.64 -
Weg
PESW-50V47AX-R38
Enclosed Starter, 15hp@230V / 30hp@460V / 40hp@575V, 50A, 480V Coil, Start / Stop+Reset, 4X, 32-50A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$336.98$336.98 -
Weg
PESW-B18V24EX-R66
Enclosed Starter, 5hp@230V / 10hp@460V / 15hp@575V, 18A, 208-240V Coil, Reset Only, 4X, 11-17A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$109.42$109.42 -
Weg
PESWS-B25D15EX-RM67
Enclosed Starter, 1.5hp@115V / 5hp@230V, 25A, 120V Coil, Reset Only, 15-23A Overload Range, Single Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$104.76$104.76 -
LS Electric
1298001300
Overload Relay, MT-32 11A 3K, Class 10, Screw Terminals, Only Use with MC-9B, MC-12B, MC-18B, MC-32B, and MC-40B Series Contactors
$62.30$62.30 -
Available Now!
Available Now!LS Electric
1298002000
Overload Relay, MT-32 34A 3K, Class 10, Screw Terminals, Only Use with MC-9B, MC-12B, MC-18B, MC-32B, and MC-40B Series Contactors
$62.30$62.30 -
LS Electric
1299000300
Overload Relay, MT-32 3.3A 3D, Class 20, Screw Terminals, Only Use with MC-9B, MC-12B, MC-18B, MC-32B, and MC-40B Series Contactors
$79.66$79.66 -
$102.33$102.33
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors