Weg
RWM840E-3-A4U840
Overload Relay, 170-840A, 3-Pole, Electronic Mounting, 10.20.30 Trigger Class, Automatic/Manual Reset, Ui = 1000V for Contactor Model CWM
$856.70$856.70 -
Weg
RWM420E-3-A4U420
Overload Relay, 85-420A, 3-Pole, Electronic Mounting, 10.20.30 Trigger Class, Automatic/Manual Reset, Ui = 1000V for Contactor Model CWM
$382.22$382.22 -
Weg
RWM40E-3-A4U040
Overload Relay, 8-40A, 3-Pole, Electronic Mounting, 10.20.30 Trigger Class, Automatic/Manual Reset, Ui = 690V for Contactor Model CWM
$95.56$95.56 -
Weg
RWM40E-3-A4U008
Overload Relay, 1.6-8A, 3-Pole, Electronic Mounting, 10.20.30 Trigger Class, Automatic/Manual Reset, Ui = 690V for Contactor Model CWM
$60.63$60.63 -
Weg
RWM40E-3-A4U002
Overload Relay, Solid State, 3 Pole, 0.4-2A, Adjustable 10, 20, 30 Trip Class, Local Reset Only, 16 Max Fuse (gL/gG) A, Ui = 690V Maximum Insulation Voltage, Direct Mounting on CWM9 to CWM40 Contactor Models
$60.63$60.63 -
Weg
RWM112E-3-A4U112
Overload Relay, 28-112A, 3-Pole, Electronic Mounting, 10.20.30 Trigger Class, Automatic/Manual Reset, Ui = 690V for Contactor Model CWM
$158.16$158.16 -
LS Electric
1347000100
IEC Contactor, General Purpose, MC-22b, 24VAC, 1NO/1NC, 3-Pole, Metasol, MC-Series
$34.75$34.75 -
Weg
RW407-1D3-U840
Overload Relay, Class 10, 3-Pole, 560-840A, Individual Mounting Type, 1D, for Contactor Models CWM450-800
$296.55$296.55 -
Weg
CWM95N-00-30V18
NEMA Contactor, 95 Amp (95A) (N), 3NO Main Contact, 110-130VAC, 50Hz/60Hz-DC, Screw Terminal, IP10 Main Circuit, IP20 Control Circuit, 117 x 75 x 126mm (4.61 x 2.95 x 4.96" (HWD)
$193.92$193.92 -
Weg
CWB38-11-30D07
IEC Contactor, 38 Amp (38A), 1NO/1NC Auxiliary Contacts, 3NO, 48VAC, 50/60Hz, Screw Terminal, UL508
$75.60$75.60 -
Weg
CWB12-11-30C07
IEC Contactor, 12 Amp (12A), 1NO/1NC Auxiliary Contacts, 3NO, 48VDC, Screw Terminal, UL508
$47.48$47.48 -
Weg
CWB38-11-30C07
IEC Contactor, 38 Amp (38A), 1NO/1NC Auxiliary Contacts, 3NO, 48VDC, Screw Terminal, UL508
$91.28$91.28
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors