-
Weg
PESWS-B40D15EX-RM70
Enclosed Starter, 40 Amp (40A) CWB Contactor, 120VAC Coil Voltage, Reset Only, 25-40A Overload Range, Single Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M06 Box Dimensions: 13 x 7.5 x 5.6" (HWD)
$238.62$238.62 -
Weg
PESWS-B9V24AX-RM62
Enclosed Starter, 0.33hp@115V / 1hp@230V, 9A, 208-240V Coil, Start / Stop+Reset, 5.6-8A Overload Range, Single Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$90.21$90.21 -
Weg
ESWE-B38D39KX-D14
Enclosed Starter for 10hp@200V, 10hp@230V, 20hp@460V, 25hp@575V Maximum hp 3-Phase Motor, 38 Amp CWB38 Contactor, 480VAC Coil Voltage without CPT, 50/60Hz, 25 - 32 Amp MPW40 Overload Relay
$663.30$663.30 -
Weg
ESWE-B9D39KX-D10
Enclosed Starter for 3hp@200V, 3hp@230V, 5hp@460V, 7-1/2hp@575V Maximum hp 3-Phase Motor, 9 Amp CWB Contactor, 480VAC Coil Voltage without CPT, 50/60Hz, 6.3 - 10 Amp MPW40 Overload Relay
$579.55$579.55 -
Weg
PESW-95V47AX-R43
Enclosed Starter, 30hp@230V / 60hp@460V / 75hp@575V, 95A, 480V Coil, Start / Stop+Reset, 4X, 63-80A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$640.20$640.20 -
Weg
PESW-B12D39EX-R64
Enclosed Starter, 7.5hp@460V / 10hp@575V, 12A, 480V Coil, Reset Only, 8-12A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$101.27$101.27 -
Weg
PESW-B25D39EX-R67
Enclosed Starter, 7.5hp@230V / 15hp@460V, 25A, 480V Coil, Reset Only, 15-23A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$129.79$129.79 -
Weg
PESW-B32V24EX-R68
Enclosed Starter, 10hp@230V / 20hp@460V / 25hp@575V, 32A, 208-240V Coil, Reset Only, 22-32A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$152.48$152.48 -
Weg
PESW-B40D15AX-R70
Enclosed Starter, 40 Amp (40A) CWB Contactor, 120VAC Coil Voltage, Start/Stop, 25-40A Overload Range, Three Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M06 Box Dimensions: 13 x 7.5 x 5.6 (HWD)
$320.10$320.10 -
Weg
PESW-B50D39EX-R71
Enclosed Starter, 50 Amp (50A) CWB Contactor, 480VAC Coil Voltage, Reset Only, 32-50A Overload Range, Three Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M06 Box Dimensions: 13 x 7.5 x 5.6 (HWD)
$328.25$328.25 -
Weg
PESW-B80D15AX-R75
Enclosed Starter, 80 Amp (80A) CWB Contactor, 120VAC Coil Voltage, Start/Stop, 63-80A Overload Range, Three Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M06 Box Dimensions: 13 x 7.5 x 5.6 (HWD)
$395.76$395.76 -
Weg
PESW-B9D15AX-R58
Enclosed Starter, 1hp@460V / 1hp@575V, 9A, 120V Coil, Start / Stop+Reset, 1.2-1.8A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$122.22$122.22
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors