-
Weg
PESW-B9D39AX-R58
Enclosed Starter, 3/4hp@460V / 1hp@575V, 9A, 480V Coil, Start / Stop+Reset, 1.2-1.8A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$122.22$122.22 -
Weg
PESW-B9D15EX-R63
Enclosed Starter, 3hp@230V / 7.5hp@575V, 9A, 120V Coil, Reset Only, 7-10A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$91.37$91.37 -
Weg
PESW-B9V24EX-R62
Enclosed Starter, 2hp@230V / 5hp@460V, 9A, 208-240V Coil, Reset Only, 4X, 5.6-8A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$91.37$91.37 -
Weg
PESW-B9V24EX-R60
Enclosed Starter, 1hp@230V / 2hp@460V / 3hp@575V, 9A, 208-240V Coil, Reset Only, 4X, 2.8-4A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$91.37$91.37 -
Weg
PESW-B9V24EX-R57
Enclosed Starter, 0.33hp@230V / 0.5hp@460V, 9A, 208-240V Coil, Reset Only, 0.8-1.2A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$91.37$91.37 -
Weg
PESW-B9V24AX-R63
Enclosed Starter, 3hp@230V / 7.5hp@575V, 9A, 208-240V Coil, Start / Stop+Reset, 7-10A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$122.22$122.22 -
Weg
PESW-B9V24AX-R59
Enclosed Starter, 0.5hp@200-230V, 208-240V Coil, 9A, 3 Phase, Start / Stop+Reset, 1.8-2.8A Overload Relay (RW27), PESW Series, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$108.15$108.15 -
Weg
PESW-B32V24AX-R68
Enclosed Starter, 10hp@230V / 20hp@460V / 25hp@575V, 32A, 208-240V Coil, Start / Stop+Reset, 4X, 22-32A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$173.44$173.44 -
Weg
PESW-B32V24EX-R68
Enclosed Starter, 10hp@230V / 20hp@460V / 25hp@575V, 32A, 208-240V Coil, Reset Only, 22-32A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$152.48$152.48 -
Weg
PESW-105V47EX-R44
Enclosed Starter, 75hp@460V, 105A, 480V Coil, Reset Only, 75-97A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$689.09$689.09 -
Weg
PESW-95V47EX-R43
Enclosed Starter, 30hp@230V / 60hp@460V / 75hp@575V, 95A, 480V Coil, Reset Only, 63-80A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$631.47$631.47 -
Weg
PESW-95V47AX-R43
Enclosed Starter, 30hp@230V / 60hp@460V / 75hp@575V, 95A, 480V Coil, Start / Stop+Reset, 4X, 63-80A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$640.20$640.20
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors