Available Now! Available Now!Weg
PESWS-B25V24AX-RM67
Enclosed Starter, 1.5hp@115V / 5hp@230V 25A 208-240V Coil, Start / Stop+Reset, 15-23A Overload Range, Single Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$97.24$97.24 -
Weg
PESW-B25D39AX-R67
Enclosed Starter, 7.5hp@230V / 15hp@460V, 25A, 480V Coil, Start / Stop+Reset, 15-23A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$137.63$137.63 -
Weg
PESW-B9V24AX-R63
Enclosed Starter, 3hp@230V / 7.5hp@575V, 9A, 208-240V Coil, Start / Stop+Reset, 7-10A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$104.72$104.72 -
Available Now! Available Now!Weg
PESW-B9D39AX-R60
Enclosed Starter, 1hp@230V / 2hp@460V / 3hp@575V, 9A, 480V Coil, Start / Stop+Reset, 4X, 2.8-4A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$104.72$104.72 -
Available Now! Available Now!Weg
PESWS-B32V24AX-RM68
Enclosed Starter, 2hp@115V / 5hp@230V, 25A, 208-240V Coil, Start / Stop+Reset, 22-32A Overload Range, Single Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$97.24$97.24 -
Available Now! Available Now!Weg
PESW-B18V24AX-R66
Enclosed Starter, 5hp@230V / 10hp@460V / 15hp@575V, 18A, 208-240V Coil, Start / Stop+Reset, 4X, 11-17A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$120.17$120.17 -
Available Now! Available Now!Weg
PESW-B32D39AX-R68
Enclosed Starter, 10hp@230V / 20hp@460V / 25hp@575V, 32 Amp (32A), 480V Coil, Start / Stop+Reset, 4X, 22-32A (RW27) Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$148.60$148.60 -
Available Now! Available Now!Weg
PESW-B32V24AX-R68
Enclosed Starter, 10hp@230V / 20hp@460V / 25hp@575V, 32A, 208-240V Coil, Start / Stop+Reset, 4X, 22-32A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$148.60$148.60 -
Available Now! Available Now!Weg
PESW-B25V24AX-R67
Enclosed Starter, 7.5hp@230V / 15hp@460V, 25A, 208-240V Coil, Start / Stop+Reset, 15-23A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$137.63$137.63 -
Weg
PESWS-B18D15AX-RM65
Enclosed Starter, 0.75hp@115V / 2hp@230V, 12A, 120V Coil, Start / Stop+Reset, 10-15A Overload Range, Single Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$90.76$90.76 -
Available Now! Available Now!Weg
PESWS-65V24AX-RM38
Enclosed Starter, 10hp@230V, 65A, 208-240V Coil, Start / Stop+Reset, 32-50A Overload Range, Single Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$234.37$234.37 -
Weg
PESW-B18D15AX-R66
Enclosed Starter, 5hp@230V / 10hp@460V / 15hp@575V, 18A, 120V Coil, Start / Stop+Reset, 4X, 11-17A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$120.17$120.17
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors