Circuit Breakers

A circuit breaker will interrupt the flow of current in an electrical circuit, safeguarding surrounding electrical components and wiring by preventing circuit overloads and short circuits.

a.k.a. MCB, MCCB, molded case breaker, supplementary protection, UL1077, UL489, UL508, MMP, manual motor protector

 

Style:
Product Price Rating Action
  • ls_electric_-_uts1200_-_mccb__54668.jpg

    LS Electric

    02142577UL

    2142577UL, UTS1200HT NG0 1200A 3P LL UL, Non-Cancellable, No Returns

    MCCB, 3 Pole, 1200 Amp (1200A), HT Breaking Capacity, NG0 Trip, Lugs Line/Load Side, UL, Molded Case Circuit Breaker, Non-Cancellable, No Returns

    $6,333.04
    $6,333.04
  • noark_-_m1s125t3l_-_mccb__18442.jpg

    Noark

    M1S125T3L

    1102170

    MCCB, UL489, M1S, 3 Pole, 125 Amp (125A), 50ka @ 240VAC, 35kA @ 480VAC, 14kA @ 600VAC, 20kA @ 600VDC, 150 A Frame, Adjustable Thermal/Magnetic Trip, Lug Line/Load Side Connection, Molded Case Circuit Breaker

  • noark_-_m1s125t3l_-_mccb__18442.jpg

    Noark

    M1S30T3L

    1100030

    MCCB, UL489, M1S, 3 Pole, 30 Amp (30A), 50kA @ 240VAC, 35kA @ 480VAC, 14kA @ 600VAC, 20kA @ 600VDC, 150 A Frame Size, Fixed Thermal/Magnetic Trip, Lug Line/Load Side Connection, Molded Case Circuit Breaker

  • noark_-_m1s125t3l_-_mccb__18442.jpg

    Noark

    M1S100T3L

    1100039

    MCCB, UL489, M1S, 3 Pole, 100 Amp (100A), 50kA @ 240VAC, 35kA @ 480VAC, 14kA @ 600VAC, 20kA @ 600VDC, 150 A Frame Size, Adjustable Thermal/Magnetic Trip, Line/Load Lug Connection, Molded Case Circuit Breaker

  • noark_-_m1s125t3l_-_mccb__18442.jpg

    Noark

    M1S40T3L

    1100032

    MCCB, UL489, M1S, 3 Pole, 40 Amp (40A), 50kA @ 240VAC, 35kA @ 480VAC, 14kA @ 480VAC, 20kA @ 600VDC, 150 A Frame, Fixed Thermal/Magnetic Trip, Lug Line/Load Side Connection, Molded Case Circuit Breaker

  • noark_-_m1s125t3l_-_mccb__18442.jpg

    Noark

    M1S50T3L

    1100034

    MCCB, UL489, M1S, 3 Pole, 50 Amp (50A), 50kA @ 240VAC, 35kA @ 480VAC, 14kA @ 480VAC, 20kA @ 600VDC, 150 A Frame, Adjustable Thermal/Fixed Magnetic Trip, Lug Line/Load Side Connection, Molded Case Circuit Breaker

  • noark_-_m1s125t3l_-_mccb__18442.jpg

    Noark

    M1S150T3L

    1102171

    MCCB, UL489, M1S, 3 Pole, 150 Amp (150A), 50kA @ 240VAC, 35kA @ 480VAC, 14kA @ 600VAC, 20kA @ 600VDC, 150 A Frame, Adjustable Thermal/Magnetic Trip, Lug Line/Load Side Connection, Molded Case Circuit Breaker

  • noark_-_m1s125t3l_-_mccb__18442.jpg

    Noark

    M1S70T3L

    1100036

    MCCB, UL489, M1S, 3 Pole, 70 Amp (70A), 50kA @ 240VAC, 35kA @ 480VAC, 14kA @ 480VAC, 20kA @ 600VDC, 150 A Frame, Adjustable Thermal/Fixed Magnetic Trip, Lug Line/Load Side Connection, Molded Case Circuit Breaker

  • noark_-_m1s125t3l_-_mccb__18442.jpg

    Noark

    M1S20T3L

    1100028

    MCCB, UL489, M1S, 3 Pole, 20 Amp (20A), 50kA @ 240VAC, 35kA @ 480VAC, 14kA @ 600VAC, 20kA @ 600VDC, 150 A Frame, Fixed Thermal/Magnetic Trip, Lug Line/Load Side Connection, Molded Case Circuit Breaker

  • LSIS_02070129UL_Primary.jpg

    LS Electric

    02070129UL

    2070129UL, UTS150L FTU 40A 3P LL UL

    MCCB, 3 Pole, 40 Amp (40A), 150kA@240VAC, Fixed Thermal/Magnetic Trip, Lugs Line/Load Side, UL Listed, 6.50 x 4.13 x 3.44" (HWD), Susol UL MCCB UTS150 Series, Molded Case Circuit Breaker

A circuit breaker will interrupt the flow of current in an electrical circuit, safeguarding surrounding electrical components and wiring by preventing circuit overloads and short circuits.

a.k.a. MCB, MCCB, molded case breaker, supplementary protection, UL1077, UL489, UL508, MMP, manual motor protector