Line Reactors/Load Reactors

Acting as electrical buffers, line and load reactors protect equipment by reducing incoming current surges and harmonic currents.

Line reactors are generally used on the line side of a drive, load reactors are often used with motor circuits on the load side.

 

Style:
Product Price Rating Action
  • RLW-001403

    MTE

    RLW-001403

    Line Reactor, 3 Phase, 14A, 1.6mH, 208/480V, Open, 3 to 10hp, 3 or 5% Impedance, See Specification Sheet, This Item is Part of the Power Quality Express Stocking Program

  • RLW-004603

    MTE

    RLW-004603

    Line Reactor, 3 Phase, 46A, 0.55mH, 208/480V, Open, 10 to 30hp, 3 or 5% Impedance, See Specification Sheet, This Item is Part of the Power Quality Express Stocking Program

  • CRX03D5CC

    Hammond Power

    CRX03D5CC

    Line Reactor, Three Phase, 3.5 Amp, 0.75hp, 240V, 60Hz, 5% Impedance, 5.09mH Inductance, 40 Watts Loss, Open Core and Coil, Terminal Block

  • CRX0343DC

    Hammond Power

    CRX0343DC

    Line Reactor, Three Phase, 343 Amp, 125hp, 240V, 60Hz, 5% Impedance, 0.0626mH Inductance, 325 Watts Loss, Open Core and Coil, Terminal Block

    $1,410.61
    $1,410.61
  • CRX0031DC

    Hammond Power

    CRX0031DC

    Line Reactor, Three Phase, 31 Amp, 10hp, 240V, 60Hz, 5% Impedance, 0.68mH Inductance, 80 Watts Loss, Open Core and Coil, Terminal Block

  • CRX0031AC

    Hammond Power

    CRX0031AC

    Line Reactor, Three Phase, 31 Amp, 10hp, 240V, 60Hz, 3% Impedance, 0.32mH Inductance, 31 Watts Loss, Open Core and Coil, Terminal Block

  • CRX0024DC

    Hammond Power

    CRX0024DC

    Line Reactor, Three Phase, 24 Amp, 7.5hp, 240V, 60Hz, 5% Impedance, 0.86mH Inductance, 60 Watts Loss, Open Core and Coil, Terminal Block

  • CRX02D4CC

    Hammond Power

    CRX02D4CC

    Line Reactor, Three Phase, 2.4 Amp, 0.5hp, 240V, 60Hz, 5% Impedance, 7.058mH Inductance, 22 Watts Loss, Open Core and Coil, Terminal Block

  • CRX0024BC

    Hammond Power

    CRX0024BC

    Line Reactor, Three Phase, 24 Amp, 7.5hp, 240V, 60Hz, 3% Impedance, 0.55mH Inductance, 68 Watts Loss, Open Core and Coil, Terminal Block

  • CRX02D4AC

    Hammond Power

    CRX02D4AC

    Line Reactor, Three Phase, 2.4 Amp, 0.5hp, 240V, 60Hz, 3% Impedance, 4.67mH Inductance, 29 Watts Loss, Open Core and Coil, Terminal Block

  • CRX0273DC

    Hammond Power

    CRX0273DC

    Line Reactor, Three Phase, 273 Amp, 100hp, 240V, 60Hz, 5% Impedance, 0.0795mH Inductance, 310 Watts Loss, Open Core and Coil, Terminal Block

    $1,321.52
    $1,321.52
  • CRX0211DC

    Hammond Power

    CRX0211DC

    Line Reactor, Three Phase, 211 Amp, 75hp, 240V, 60Hz, 5% Impedance, 0.096mH Inductance, 225 Watts Loss, Open Core and Coil, Terminal Block

Acting as electrical buffers, line and load reactors protect equipment by reducing incoming current surges and harmonic currents.

Line reactors are generally used on the line side of a drive, load reactors are often used with motor circuits on the load side.