Contactors, Starters, Overload Relays

A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors

Style:
Product Price Rating Action
  • ESW-B9D15E-R27

    Weg

    ESW-B9D15E-R27

    Enclosed Starter, 1.5hp@230V, 9A, 120V Coil3 Ph, Reset Only, NEMA 1, 4-6.3A Overload Range, 3 Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination

  • 0705101700

    LS Electric

    0705101700

    Manual Motor Starter, 40A, (28-40A), 32F, Standard Breaking Capacity, Overload & Instantaneous Protection, This is the Latest Version of (0705008900, 705008900, MMS-32S 40A EXP)

  • PESWS-50V24AX-RM36

    Weg

    PESWS-50V24AX-RM36

    Enclosed Starter, 7.5hp@230V, 50 Amp (50A), 208-240V Coil Voltage, Start/Stop+Reset, 25-40A Overload Range (RW67), Single Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination Across the Line Starter

  • 0705103700

    LS Electric

    0705103700

    Manual Motor Starter, 0.4A, (0.25-0.4A), 32F, High Breaking Capacity, Overload & Instantaneous Protection, This is the Latest Version of (0705000300, 705000300, MMS-32H 0.4A EXP)

  • 0707103000

    LS Electric

    0707103000

    Manual Motor Starter, 100A, 100F, High Breaking Capacity, Instantaneous Protection Only, NCNR, This is the Latest Version of (0707003000, 707003000, MMS-100HI 100A EXP)

  • 0707101000

    LS Electric

    0707101000

    Manual Motor Starter, 100A, (80-100A), 100F, Standard. Breaking Capacity, Overload & Instantaneous Protection, This is the Latest Version of (0707001000, 707001000, MMS-100S 100A EXP)

  • Available Now!
    ESWS-B9D15E-RM27
    Available Now!

    Weg

    ESWS-B9D15E-RM27

    Enclosed Starter, 9A, Reset Only, 4-6.3A Overload Range, Single Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination

  • ESW-B38D15E-R35

    Weg

    ESW-B38D15E-R35

    Enclosed Starter, 10hp@230V, 38A, 120V Coil, Reset Only, NEMA 1, 25-40A Overload Range, 3 Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination

  • 0705103800

    LS Electric

    0705103800

    Manual Motor Starter, 0.63A, (0.4-0.63A), 32F, High Breaking Capacity, Overload & Instantaneous Protection, This is the Latest Version of (0705000400, 705000400, MMS-32H 0.63A EXP)

  • 0705106800

    LS Electric

    0705106800

    Manual Motor Starter, 40A, 32F, High Breaking Capacity, Instantaneous Protection Only, NCNR, This is the Latest Version of (0705009100, 705009100, MMS-32HI 40A EXP)

A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors