Contactors, Starters, Overload Relays

A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors

Style:
Product Price Rating Action
  • ESW-B9V24A-R23

    Weg

    ESW-B9V24A-R23

    Enclosed Starter, 9 Amp (9A), CWB Contactor, 180-208VAC, 50Hz | 208-240VAC, 60Hz, Start/Stop+Reset, 0.8-1.2A O/L Range, 3 Phase NEMA 1 Metallic Enclosure, Full Voltage Non-Combination Across the Line Starter, M04 Box: 9.5 x 5.5 x 5.0" (HWD)

  • ESWS-B9V24A-RM27

    Weg

    ESWS-B9V24A-RM27

    Enclosed Starter, 9A, 208-240VCoil, Start/Stop + Reset , 4-6.3A Overload Range, Single Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination

  • ESWF-9V24N4-D07

    Weg

    ESWF-9V24N4-D07

    Combination Motor Starter, 0.5hp/200V, 0.5hp/230V, 1.5hp/460, 1.5hp/575V, 208-240VAC Coil Voltage, 1.6-2.5A O/L Range, Wall Mount, Type 4/12 Metal Enclosure, HOA-Start/Stop/Reset, Circuit Breaker Rotary Handle Disconnect, Full Voltage, Non-Reversing

  • PESW-B9V24AX-R57

    Weg

    PESW-B9V24AX-R57

    Enclosed Starter, 0.33hp@230V / 0.5hp@460V, 9A, 208-240V Coil, Start / Stop+Reset, 4X, 0.8-1.2A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

  • PESWS-B9V24EX-RM61

    Weg

    PESWS-B9V24EX-RM61

    Enclosed Starter, 0.75hp@230V, 9A, 208-240V Coil, Reset Only, 4-6.3A Overload Range, Single Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

  • PESWS-B9V24AX-RM61

    Weg

    PESWS-B9V24AX-RM61

    Enclosed Starter, 0.75hp@230V, 9A, 208-240V Coil, Start / Stop+Reset, 4-6.3A Overload Range, Single Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

  • PESW-B9V24EX-R57

    Weg

    PESW-B9V24EX-R57

    Enclosed Starter, 0.33hp@230V / 0.5hp@460V, 9A, 208-240V Coil, Reset Only, 0.8-1.2A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors