Contactors, Starters, Overload Relays

A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors

Style:
Product Price Rating Action
  • Available Now!
    ESW-B9D15A-R29
    Available Now!

    Weg

    ESW-B9D15A-R29

    Enclosed Starter, 3hp@230V, 9A, 120V Coil, Start/Stop+Reset, NEMA 1, 7-10A Overload Range, 3 Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination

  • ESW-B9D15E-R29

    Weg

    ESW-B9D15E-R29

    Enclosed Starter, 3hp@230V, 9A, 120V Coil, Reset Only, NEMA 1, 7-10A Overload Range, 3 Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination

  • Available Now!
    ESW-B9V24A-R29
    Available Now!

    Weg

    ESW-B9V24A-R29

    Enclosed Starter, 3hp@230V, 9A, 208-240V Coil, Start/Stop+Reset, NEMA 1, 7-10A Overload Range, 3 Phase, Metallic Enclosure, NEMA 1, Full Voltage, Non-Reversing, Non-Combination

  • ESW-B9V24E-R29

    Weg

    ESW-B9V24E-R29

    Enclosed Starter, 3hp@230V, 9 Amp (9A), 208-240V Coil, Reset Only, 7-10A (RW27) Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination

  • PESW-B9D45AX-R60

    Weg

    PESW-B9D45AX-R60

    Enclosed Starter, 9 Amp (9A) CWB Contactor, 600V Coil Voltage, Start/Stop, 2.8-4A Overload Range, Three Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M04 Box Dimensions: 9.5 x 5.5 x 5.0" (HWD)

  • PESW-B9D45EX-R60

    Weg

    PESW-B9D45EX-R60

    Enclosed Starter, 9 Amp (9A) CWB Contactor, 600V Coil Voltage, Reset Only, 2.8-4A Overload Range, Three Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M04 Box Dimensions: 9.5 x 5.5 x 5.0" (HWD)

  • ESWE-B9V24KX-D10

    Weg

    ESWE-B9V24KX-D10

    Enclosed Starter for 3hp@200V, 3hp@230V, 5hp@460V, 7-1/2hp@575V Maximum hp 3-Phase Motor, 9 Amp CWB Contactor, 208-240VAC Coil Voltage without CPT, 60Hz, 6.3 - 10 Amp MPW40 Overload Relay

  • ESWE-B9D39KX-D10

    Weg

    ESWE-B9D39KX-D10

    Enclosed Starter for 3hp@200V, 3hp@230V, 5hp@460V, 7-1/2hp@575V Maximum hp 3-Phase Motor, 9 Amp CWB Contactor, 480VAC Coil Voltage without CPT, 50/60Hz, 6.3 - 10 Amp MPW40 Overload Relay

  • ESWE-B9D15KX-D10

    Weg

    ESWE-B9D15KX-D10

    Enclosed Starter for 3hp@200V, 3hp@230V, 5hp@460V, 7-1/2hp@575V Maximum hp 3-Phase Motor, 9 Amp CWB Contactor, 120VAC Coil Voltage without CPT, 50/60Hz, 6.3 - 10 Amp MPW40 Overload Relay

  • PESW-B9D39EX-R60

    Weg

    PESW-B9D39EX-R60

    Enclosed Starter, 1hp@230V / 2hp@460V / 3hp@575V, 9A, 480V Coil, Reset Only, 2.8-4A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

  • PESW-B9V24AX-R60

    Weg

    PESW-B9V24AX-R60

    Enclosed Starter, 1hp@230V / 2hp@460V / 3hp@575V, 9A, 208-240V Coil, Start / Stop+Reset, 4X, 2.8-4A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

  • PESW-B9D15EX-R60

    Weg

    PESW-B9D15EX-R60

    Enclosed Starter, 1hp@230V / 2hp@460V / 3hp@575V, 9A, 120V Coil, Reset Only, 2.8-4A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors