Weg
ESW-B12D39E-R30
Enclosed Starter, 7.5hp@460V, 12 Amp (12A), 480V Coil, Reset Only, 8-12.5A (RW27) Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination
$93.96$93.96 -
Available Now! Available Now!Weg
ESW-B12D39A-R30
Enclosed Starter, 7.5hp@460V, 12 Amp (12A), 480V Coil, Start/Stop+Reset, 8-12.5A (RW27) Overload Range, 3 Phase, NEMA 1 Metallic Enclosure, Full Voltage, Non-Reversing, Non-Combination
$122.58$122.58 -
$21.61$21.61
-
Weg
CWC012-10-30V47
Mini Contactor, 12 Amp, 1NO Auxiliary Contacts, 3NO Power Poles, 400-415V 50Hz/480V 60Hz, Screw Terminal, IP20, 2.28 x 1.77 x 2.05" (HWD), CWC Series
$18.03$18.03 -
Weg
CWC012-01-30V47
Mini Contactor, 12 Amp, 1NC Auxiliary Contacts, 3NO Power Poles, 400-415V 50Hz/480V 60Hz, Screw Terminal, IP20, 2.28 x 1.77 x 2.05" (HWD), CWC Series
$18.03$18.03 -
Weg
CWC012-00-40V47
Mini Contactor, 12 Amp, 4NO Power Poles, 400-415V 50Hz/480V 60Hz, Screw Terminal, IP20, 2.28 x 1.77 x 2.05" (HWD), CWC Series
$18.60$18.60 -
Weg
CWC012-00-22V47
Mini Contactor, 12 Amp, 2NO/2NC Power Poles, 400-415V 50Hz/480V 60Hz, Screw Terminal, IP20, 2.28 x 1.77 x 2.05" (HWD), CWC Series
$18.60$18.60 -
Weg
CWB12-11-30D39
Contactor, IEC, 12A, 3 NO Pole, 480VAC Coil, 50/60Hz, Auxiliary 1NO/1NC, Screw Terminal, UL508
$32.96$32.96 -
Available Now! Available Now!Weg
CWM12-10-30V47
Contactor, IEC, 12 Amps, 1NO, 480VAC, 3-Pole, UL508, Use RW Overload Relay
$38.27$38.27 -
$38.27$38.27
-
Weg
PESW-B12D39EX-R64
Enclosed Starter, 7.5hp@460V / 10hp@575V, 12A, 480V Coil, Reset Only, 8-12A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$86.77$86.77 -
Available Now! Available Now!Weg
PESW-B12D39AX-R64
Enclosed Starter, 7.5hp@460V / 10hp@575V, 12A, 480V Coil, Start / Stop+Reset, 8-12A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination
$113.20$113.20
A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.
A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.
a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors