A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors

Style:
Product Price Rating Action
  • PESW-B9D45EX-R61

    Weg

    PESW-B9D45EX-R61

    Enclosed Starter, 9 Amp (9A) CWB Contactor, 600V Coil Voltage, Reset Only, 4-6.3A Overload Range, Three Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M04 Box Dimensions: 9.5 x 5.5 x 5.0" (HWD)

  • PESW-B9D15EX-R61

    Weg

    PESW-B9D15EX-R61

    Enclosed Starter, 9 Amp (9A) CWB Contactor, 120VAC Coil Voltage, Reset Only, 4-6.3A Overload Range, Three Phase, NEMA 4X, Non-Metallic, Non-Reversing, Non-Combination Across the Line Starter, M04 Box Dimensions: 9.5 x 5.5 x 5.0" (HWD)

  • ESWE-B18V24KX-D11

    Weg

    ESWE-B18V24KX-D11

    Enclosed Starter for 5hp@200V, 5hp@230V, 10hp@460V, 15hp@575V Maximum hp 3-Phase Motor, 18 Amp CWB Contactor, 208-240VAC Coil Voltage without CPT, 60Hz, 10 - 16 Amp MPW40 Overload Relay

  • ESWE-B18D39KX-D11

    Weg

    ESWE-B18D39KX-D11

    Enclosed Starter for 5hp@200V, 5hp@230V, 10hp@460V, 15hp@575V Maximum hp 3-Phase Motor, 18 Amp CWB Contactor, 480VAC Coil Voltage without CPT, 50/60Hz, 10 - 16 Amp MPW40 Overload Relay

  • ESWE-B18D15KX-D11

    Weg

    ESWE-B18D15KX-D11

    Enclosed Starter for 5hp@200V, 5hp@230V, 10hp@460V, 15hp@575V Maximum hp 3-Phase Motor, 18 Amp CWB Contactor, 120VAC Coil Voltage without CPT, 50/60Hz, 10 - 16 Amp MPW40 Overload Relay

  • PESWS-B32D15AX-RM68

    Weg

    PESWS-B32D15AX-RM68

    Enclosed Starter, 2hp@115V / 5hp@230V, 32A, 120V Coil, 50 / 60Hz, Start / Stop + Reset, 22-32A Overload Range, Single Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

  • PESW-B9D15AX-R61

    Weg

    PESW-B9D15AX-R61

    Enclosed Starter, 1hp@200V / 1.5hp,@230V, 9A, 120V Coil, Start / Stop+Reset, 4.0-6.3 Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

  • PESW-B9V24AX-R62

    Weg

    PESW-B9V24AX-R62

    Enclosed Starter, 2hp@230V / 5hp@460V, 9A, 208-240V Coil, Start / Stop+Reset, 4X, 5.6-8A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

  • Available Now!
    PESW-B9V24AX-R61
    Available Now!

    Weg

    PESW-B9V24AX-R61

    Enclosed Starter, 1.5hp@230V / 3hp@460V / 5hp@575V, 9A, 208-240V Coil, Start / Stop+Reset, 4X, 4-6.3A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

  • PESW-B9D39EX-R62

    Weg

    PESW-B9D39EX-R62

    Enclosed Starter, 2hp@230V / 5hp@460V, 9A, 480V Coil, Reset Only, 5.6-8A Overload Range, 3 Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

  • Available Now!
    PESWS-B32V24AX-RM68
    Available Now!

    Weg

    PESWS-B32V24AX-RM68

    Enclosed Starter, 2hp@115V / 5hp@230V, 25A, 208-240V Coil, Start / Stop+Reset, 22-32A Overload Range, Single Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

  • PESWS-B32D15EX-RM68

    Weg

    PESWS-B32D15EX-RM68

    Enclosed Starter, 2hp@115V / 5hp@230V, 25A, 120V Coil, Reset Only, 22-32A Overload Range, Single Phase, Non-Metallic Enclosure, NEMA 4X, Full Voltage, Non-Reversing, Non-Combination

A motor starter is a contactor plus an overload relay; without an overload it is just a contactor.

A motor starter starts and stops a connected motor load and will provide protection in case of a sudden loss of power or if the motor overloads. A contactor is similar to a relay (but can handle larger amounts of electrical power and handle higher voltage loads) and is used for switching current on and off in a circuit. Contactors are used to control electrical loads and motors without providing overload protection.

a.k.a. motor starter, IEC contactor, dp contactor, thermal overload relay, motor protectors